THE ESSENTIAL EUROPE
SAINT-GOBAIN GLASS – FACADE / 11 / SAINT-GOBAIN GLASS – FACADE 10 Coating color in reflection temperable or to-be-tempered (II) annealed Light transmission LT 1 [%] External reflection LRe [%] DGU with all panes PLANICLEAR® DGU with PLANITHERM® XN on face #3 (PLANICLEAR®) Processing possibilities Light transmission LT 1 Solar factor g-value 1 External reflection LRe 1 Internal reflection LRi 1 Carbon footprint 7,8 (annealed / tempered) Ug-value 2 Light transmission LT 1 Solar factor g-value 1 Selectivity LT / g External reflection LRe 1 Internal reflection LRi 1 Carbon footprint 7,8 (annealed / tempered) Ug-value 2 Tempering Lamination tested towards PVB 4 Bending 5 Enamelling 6 Solar factor g-value 1 [%] [%] [%] [%] [%] [kg CO₂eq/m² ] [W/m 2 K] [%] [%] [%] [%] [kg CO₂eq/m²] [W/m 2 K] Selective solar control coating with good thermal insulation COOL-LITE ® K in double glazing unit (6 | 16 | 4 mm, 90% Argon, coating on face #2) on PLANICLEAR ® Values given according to the standards EN 410 and EN 673 DOUBLE GLAZING UNIT 6 | 16 | 4 mm: Weight 25 kg/m 2 - Assessed sound reduction Index Rw (C, Ctr) 3 : 35(-1;-5) dB COOL-LITE ® KNT 164 Neutral • 58 47 15 10 39 / 43 1.5 57 42 1.36 13 7 40 / 44 1.1 • • COOL-LITE ® KNT 155 Neutral • 48 38 17 10 39 / 43 1.4 48 35 1.37 16 7 40 / 44 1.1 • • COOL-LITE ® KS 146 II Silver • 43 30 33 19 43 1.2 42 29 1.45 33 16 44 1.1 • • COOL-LITE ® KS 147 Silver • 44 31 43 38 39 1.1 43 30 1.43 42 34 40 1.1 • COOL-LITE ® KNT 140 Neutral • 38 29 23 12 39/ 43 1.3 38 27 1.41 22 9 40 / 44 1.1 • • COOL-LITE ® KS 138 II Silver • 37 26 39 20 43 1.2 36 25 1.44 38 17 44 1.1 • • COOL-LITE ® KG 137 tempered Gold • 35 29 34 32 43 1.2 34 27 1.26 33 28 44 1.1 • COOL-LITE ® KG 137 annealed Gold • 35 29 31 29 39 1.2 34 27 1.26 30 25 40 1.1 • Coating color inreflection temperable annealed Light transmission LT 1 [%] External reflection LRe [%] Monolithic glass with coating on face #2 DGU with PLANITHERM® XN on face #3 Processing possibilities Light transmission LT 1 Solar factor g-value 1 External reflection LRe 1 Internal reflection LRi 1 Carbon footprint 7,8 (annealed / tempered) Ug-value 2 Light transmission LT 1 Solar factor g-value 1 Selectivity LT / g External reflection LRe 1 Internal reflection LRi 1 Carbon footprint 7,8 (annealed / tempered) Ug-value 2 Tempering Lamination tested towards PVB 4 Bending 5 Enamelling 6 Solar factor g-value 1 [%] [%] [%] [%] [%] [kg CO₂eq/m² ] [W/m 2 K] [%] [%] [%] [%] [kg CO₂eq/m²] [W/m 2 K] Solar control coating offering full flexibility for processing COOL-LITE ® ST as monolithic glass 6mm or in double glazing unit (6 | 16 | 4 mm, 90% Argon, coating on face #2) on PLANICLEAR ® Values given according to the standards EN 410 and EN 673 DOUBLE GLAZING UNIT 6 | 16 | 4 mm : Weight 25 kg/m 2 - Assessed sound reduction Index Rw (C, Ctr) 3 : 35(-1;-5) dB COOL-LITE ® ST BRIGHT SILVER DIAMANT® Silver • 67 71 30 31 18 / 24 5.7 62 52 1.19 32 31 42 / 46 1.1 • • • • COOL-LITE ® ST BRIGHT SILVER PLANICLEAR® Silver • 67 69 30 31 17 / 23 5.7 61 50 1.22 32 30 40 / 44 1.1 • • • • COOL-LITE ® ST 167 (on PLANICLEAR®) Neutral • 67 69 19 19 17 / 23 5.6 61 49 1.24 21 21 40 / 44 1.1 • • • • COOL-LITE ® ST 150 (on PLANICLEAR®) Neutral • 51 56 18 17 17 / 23 5.6 46 38 1.21 19 19 40 / 44 1.1 • • • • COOL-LITE ® ST 136 (on PLANICLEAR®) Neutral • 37 44 22 18 17 / 23 5.5 33 28 1.18 23 20 40 / 44 1.1 • • • • COOL-LITE ® STB 136 (on PLANICLEAR®) Blue • 36 44 18 15 17 / 23 5.4 32 28 1.14 19 17 40 / 44 1.1 • • • COOL-LITE ® ST 120 (on PLANICLEAR®) Neutral • 21 30 32 26 17 / 23 5.2 19 17 1.14 32 26 40 / 44 1.1 • • • • COOL-LITE ® STB 120 (on PLANICLEAR®) Blue • 22 32 21 29 17 / 23 5.2 20 18 1.11 21 29 40 / 44 1.1 • • • 100 90 80 70 60 50 40 30 20 10 0 10 20 30 40 50 100 90 80 70 60 50 40 30 20 10 0 10 20 30 40 50 1 according to EN 410; 2 according to EN 673; 3 according to EN 12758 4 Solar control coating in contact with PVB modifies performances and aesthetics. Some restrictions may occur. Please contact us to get the approved list. 5 Bending results depend on the process/technology used; trials should be done for validation. 6 Screen-printing/roller coating/spray/digital printing inks and enamels validation is required. Some restrictions may occur, please contact us for details. 7 Global Warming Potential (GWP A1-A3 Stages) values with PLANICLEAR ® and ORAÉ ® are calculations made with Calumen ® for each composition of insulated glazing unit (IGU) on the basis of the standard EN 15804+A2. Detailed environmental data are documented in the available Environmental Product Declarations (EPD) of PLANICLEAR ® and ORAÉ ® . Only complete EPD can be verified by an external third party. 8 All panes of the IGU with the same substrate; first pane respectively annealed and/or tempered (II) with the same glass compositions; counter panes always annealed OUR COOL-LITE® SOLAR CONTROL COATED GLASS FOR FACADES in Double Glazing Units DGU I I LOOKING FOR OTHER CONFIGURATIONS? GO TO OUR ONLINE GLAZING CONFIGURATOR!
Made with FlippingBook
RkJQdWJsaXNoZXIy MTMyNDA4