THE ESSENTIAL EUROPE

SAINT-GOBAIN GLASS – FACADE / 15 / SAINT-GOBAIN GLASS – FACADE 14 Coating color in reflection temperable or to-be-tempered (II) annealed Light transmission LT 1 [%] External reflection LRe [%] TGU with PLANITHERM® XN on face #5 (PLANICLEAR®) TGU with PLANITHERM® XN on face #3 and #5 (PLANICLEAR®) Processing possibilities Light transmission LT 1 Solar factor g-value 1 External reflection LRe 1 Internal reflection LRi 1 Carbon footprint 7,8 (annealed / tempered) Ug-value 2 Light transmission LT 1 Solar factor g-value 1 Selectivity LT / g External reflection LRe 1 Internal reflection LRi 1 Carbon footprint 7,8 (annealed / tempered) Ug-value 2 Tempering Lamination tested towards PVB 4 Bending 5 Enamelling 6 Solar factor g-value 1 [%] [%] [%] [%] [%] [kg CO₂eq/m² ] [W/m 2 K] [%] [%] [%] [%] [kg CO₂eq/m²] [W/m 2 K] Selective solar control coating with good thermal insulation COOL-LITE ® K in triple glazing unit (6 | 12 | 4 | 12 | 4 mm, 90% Argon, coating on face #2 and PLANITHERM® XN on face #5 and/or #3) on PLANICLEAR ® Values given according to the standards EN 410 and EN 673 TRIPLE GLAZING UNIT 6 | 12 | 4 | 12 | 4 mm : Weight 35 kg/m 2 - Assessed sound reduction Index Rw (C, Ctr) 3 : 36(-1;-5) dB COOL-LITE ® KNT 164 Neutral • 52 39 16 13 57 / 61 0.8 52 37 1.41 14 11 58 / 62 0.7 • • COOL-LITE ® KNT 155 Neutral • 43 32 18 14 57 / 61 0.8 43 30 1.43 17 11 58 / 62 0.7 • • COOL-LITE ® KS 146 II Silver • 39 26 34 21 61 0.7 38 25 1.52 33 18 62 0.7 • • COOL-LITE ® KS 147 Silver • 40 28 44 36 57 0.7 39 26 1.50 43 33 58 0.7 • COOL-LITE ® KNT 140 Neutral • 34 25 24 15 57 / 61 0,8 34 23 1.48 23 12 58 / 62 0.7 • • COOL-LITE ® KS 138 II Silver • 33 23 40 22 61 0.7 33 22 1.50 39 19 62 0.7 • • COOL-LITE ® KG 137 tempered Gold • 32 25 34 31 61 0.7 31 24 1.29 33 28 62 0.7 • COOL-LITE ® KG 137 annealed Gold • 32 25 31 29 57 0.7 31 24 1.29 30 26 58 0.7 • Coating color in reflection temperable annealed Light transmission LT 1 [%] External reflection LRe [%] TGU with PLANITHERM® XN on face #5 (PLANICLEAR®) TGU with PLANITHERM® XN on face #3 and #5 (PLANICLEAR®) Processing possibilities Light transmission LT 1 Solar factor g-value 1 External reflection LRe 1 Internal reflection LRi 1 Carbon footprint 7,8 (annealed / tempered) Ug-value 2 Light transmission LT 1 Solar factor g-value 1 Selectivity LT / g External reflection LRe 1 Internal reflection LRi 1 Carbon footprint 7,8 (annealed / tempered) Ug-value 2 Tempering Lamination tested towards PVB 4 Bending 5 Enamelling 6 Solar factor g-value 1 [%] [%] [%] [%] [%] [kg CO₂eq/m² ] [W/m 2 K] [%] [%] [%] [%] [kg CO₂eq/m²] [W/m 2 K] Solar control coating offering full flexibility for processing COOL-LITE ® ST in triple glazing unit (6 | 12 | 4 | 12 | 4 mm, 90% Argon, coating on face #2 and PLANITHERM® XN on face #5 and/or #3) on PLANICLEAR ® Values given according to the standards EN 410 and EN 673 TRIPLE GLAZING UNIT 6 | 12 | 4 | 12 | 4 mm : Weight 35 kg/m 2 - Assessed sound reduction Index Rw (C, Ctr) 3 : 36(-1;-5) dB COOL-LITE ® ST BRIGHT SILVER DIAMANT® Silver • 58 49 36 34 59 / 63 1.0 57 45 1.27 34 31 61 / 64 0.7 • • • • COOL-LITE ® ST BRIGHT SILVER PLANICLEAR® Silver • 57 47 35 33 57 / 61 1.0 55 43 1.28 33 30 58 / 62 0.7 • • • • COOL-LITE ® ST 167 (on PLANICLEAR®) Neutral • 56 45 24 25 57 / 61 1.0 55 42 1.31 22 22 58 / 62 0.7 • • • • COOL-LITE ® ST 150 (on PLANICLEAR®) Neutral • 42 35 21 23 57 / 61 1.0 42 32 1.31 20 20 58 / 62 0.7 • • • • COOL-LITE ® ST 136 (on PLANICLEAR®) Neutral • 31 26 24 24 57 / 61 1.0 30 24 1.25 23 21 58 / 62 0.7 • • • • COOL-LITE ® STB 136 (on PLANICLEAR®) Blue • 30 26 19 22 57 / 61 1,0 29 23 1.26 19 19 58 / 62 0.7 • • • COOL-LITE ® ST 120 (on PLANICLEAR®) Neutral • 18 16 33 29 57 / 61 1.0 17 15 1.13 32 26 58 / 62 0.7 • • • • COOL-LITE ® STB 120 (on PLANICLEAR®) Blue • 19 17 22 32 57 / 61 1,0 18 15 1.20 21 28 58 / 62 0.7 • • • 100 90 80 70 60 50 40 30 20 10 0 10 20 30 40 50 100 90 80 70 60 50 40 30 20 10 0 10 20 30 40 50 1 according to EN 410; 2 according to EN 673; 3 according to EN 12758 4 Solar control coating in contact with PVB modifies performances and aesthetics. Some restrictions may occur. Please contact us to get the approved list. 5 Bending results depend on the process/technology used; trials should be done for validation. 6 Screen-printing/roller coating/spray/digital printing inks and enamels validation is required. Some restrictions may occur, please contact us for details. 7 Global Warming Potential (GWP A1-A3 Stages) values with PLANICLEAR ® and ORAÉ ® are calculations made with Calumen ® for each composition of insulated glazing unit (IGU) on the basis of the standard EN 15804+A2. Detailed environmental data are documented in the available Environmental Product Declarations (EPD) of PLANICLEAR ® and ORAÉ ® . Only complete EPD can be verified by an external third party. 8 All panes of the IGU with the same substrate; first pane respectively annealed and/or tempered (II) with the same glass compositions; counter panes always annealed OUR COOL-LITE® SOLAR CONTROL COATED GLASS FOR FACADES in Triple Glazing Units TGU I I I LOOKING FOR OTHER CONFIGURATIONS? GO TO OUR ONLINE GLAZING CONFIGURATOR!

RkJQdWJsaXNoZXIy MTMyNDA4