/ SAINT-GOBAIN BUILDING GLASS – FACADE 46 Values given according to the standards EN 410 & EN 673 - 2011 Product Color in Reflection LT (%) Solar Factor g-value Shading coefficient SC Selectivity LT / g External Light Reflectance LRe (%) U- (E (W To be tempered / Annealed coating (if available) WINTER AND SUMMER COMFORT High Performance Glass COOL-LITE SKN for double glazing (6+16+4mm) on PLANICLEAR or DIAMANT COOL-LITE SKN 145 Neutral 41 0,22 0,25 1,86 19 COOL-LITE SKN 144 II Neutral 42 0,23 0,26 1,83 20 COOL-LITE SKN 044 II Extra clear 43 0,23 0,26 1,87 21 High Performance Glass COOL-LITE KT for double glazing (6+16+4mm) on PLANICLEAR COOL-LITE KN 166 II Neutral 61 0,39 0,45 1,56 22 COOL-LITE KNT 164 Neutral 58 0,47 0,54 1,23 15 COOL-LITE KNT 155 Neutral 48 0,38 0,44 1,26 17 COOL-LITE KNT 140 Neutral 38 0,29 0,33 1,31 23 COOL-LITE KBT 140 Blue 37 0,29 0,33 1,28 24 * *1 *2 *3 *4 *5 COOL-LITE SKN 154 may have a slight colour deviation in transmission with the SKN 154 II heat treated version. Validation of a prototype is recommended if both versions are used on the same facade. Solar control coating in contact with PVB modifies performances and aesthetics. Please contact us to get the approved PVB list. This coating can be laminated for use on a facade up to 1500m 2 and project must be made from a single production batch from SGG. Bending results depend on the process; trials should be done for validation. Validation should be taken with the digital printing inks and enamels. Screen-printing, roller coating, spray and digital printing validation required.