82 83 COOL-LITE® SKN in triple glazing unit CLIMATOP® (6 | 12 | 4 | 12 | 4 mm, 90% Argon, coating on face #2 with PLANITHERM® XN on face #5) on PLANICLEAR® or DIAMANT® Highly selective solar control coating with reinforced thermal insulation Values given according to the standards 1 EN 410, 2 EN 673 and 3 EN 12758 TRIPLE GLAZING UNITS - CLIMATOP® OUR PRODUCTS coating to be tempered / annelead processing possibilities 14 16 0.7 35.0 36(-1;-5) to be tempered yes 5 14 16 0.7 35.0 36(-1;-5) 14 16 0.7 35.0 36(-1;-5) to be tempered yes 5 14 16 0.7 35.0 36(-1;-5) 15 18 0.7 35.0 36(-1;-5) to be tempered yes 8 yes 5 15 18 0.7 35.0 36(-1;-5) 15 17 0.7 35.0 36(-1;-5) to be tempered yes 8 yes 5 15 17 0.7 35.0 36(-1;-5) 18 21 0.7 35.0 36(-1;-5) to be tempered yes 8 yes 5 18 20 0.7 35.0 36(-1;-5) yes 8 18 20 0.7 35.0 36(-1;-5) to be tempered yes 8 yes 5 18 20 0.7 35.0 36(-1;-5) yes 8 19 24 0.7 35.0 36(-1;-5) to be tempered yes 8 yes 5 20 23 0.7 35.0 36(-1;-5) yes 8 19 23 0.7 35.0 36(-1;-5) to be tempered yes 8 yes 5 20 23 0.7 35.0 36(-1;-5) yes 8 20 18 0.7 35.0 36(-1;-5) 20 17 0.7 35.0 36(-1;-5) 22 18 0.7 35.0 36(-1;-5) to be tempered yes 8 21 17 0.7 35.0 36(-1;-5) to be tempered yes 8 13 16 0.7 35.0 36(-1;-5) to be tempered yes 5 13 16 0.7 35.0 36(-1;-5) 13 16 0.7 35.0 36(-1;-5) to be tempered yes 5 13 16 0.7 35.0 36(-1;-5) 13 18 0.7 35,0 36(-1;-5) to be tempered 13 17 0.7 35.0 36(-1;-5) 12 17 0.7 35.0 36(-1;-5) to be tempered 12 16 0.7 35.0 36(-1;-5) 31 20 0.7 35.0 36(-1;-5) to be tempered yes 5 30 20 0.7 35.0 36(-1;-5) to be tempered yes 5 17 20 0.7 35.0 36(-1;-5) to be tempered yes 5 17 20 0.7 35.0 36(-1;-5) to be tempered yes 5 COOL-LITE® SKN 083 II extra neutral 69 0.38 0.44 1.82 COOL-LITE® SKN 083 extra neutral 69 0.38 0.44 1.82 COOL-LITE® SKN 183 II neutral 67 0.37 0.43 1.81 COOL-LITE® SKN 183 neutral 67 0.37 0.43 1.81 COOL-LITE® SKN 076 II extra neutral 65 0.35 0.41 1.86 COOL-LITE® SKN 076 extra neutral 65 0.35 0.41 1.86 COOL-LITE® SKN 176 II neutral 63 0.35 0.40 1.80 COOL-LITE® SKN 176 neutral 63 0.35 0.40 1.80 COOL-LITE® SKN 065 II extra neutral 57 0.32 0.37 1.78 COOL-LITE® SKN 065 extra neutral 57 0.33 0.37 1.73 COOL-LITE® SKN 165 II neutral 55 0.31 0.36 1.77 COOL-LITE® SKN 165 neutral 55 0.32 0.36 1.72 COOL-LITE® SKN 054 II extra neutral 48 0.27 0.31 1.78 COOL-LITE® SKN 054 extra neutral 48 0.27 0.31 1.78 COOL-LITE® SKN 154 II neutral 47 0.26 0.30 1.81 COOL-LITE® SKN 154 neutral 47 0.26 0.30 1.81 COOL-LITE® SKN 045 neutral 38 0.21 0.24 1.81 COOL-LITE® SKN 145 neutral 37 0.20 0.23 1.85 COOL-LITE® SKN 044 II extra neutral 39 0.21 0.25 1.86 COOL-LITE® SKN 144 II neutral 38 0.21 0.24 1.81 COOL-LITE® XTREME 70/33 II DIAMANT® extra neutral 65 0.32 0.36 2.03 COOL-LITE® XTREME 70/33 DIAMANT® extra neutral 65 0.32 0.36 2.03 COOL-LITE® XTREME 70/33 II neutral 63 0.31 0.35 2.03 COOL-LITE® XTREME 70/33 neutral 63 0.31 0.36 2.03 NEW COOL-LITE® XTREME 61/29 II DIAMANT® extra neutral 56 0.27 0.32 2.07 NEW COOL-LITE® XTREME 61/29 DIAMANT® extra neutral 56 0.28 0.32 2.00 NEW COOL-LITE® XTREME 61/29 II neutral 55 0.27 0.31 2.04 NEW COOL-LITE® XTREME 61/29 neutral 55 0.27 0.31 2.04 COOL-LITE® XTREME SILVER II DIAMANT® bright silver 45 0.24 0.27 1.88 COOL-LITE® XTREME SILVER II silver 44 0.23 0.27 1.91 COOL-LITE® XTREME 50/22 II DIAMANT® extra neutral 44 0.20 0.23 2.20 COOL-LITE® XTREME 50/22 II neutral 43 0.19 0.22 2.26 color in reflection light transmission LT 1 [%] solar factor g-value 1 shading coefficient SC selectivity LT / g screenprinting & enamelling 6 bending 5 lamination tested towards PVB 4 tempering use as mono glazing (coating on surface #2) weight [kg/m 2 ] Ug-value 2 [W/m 2 K] reflection outside LRe [%] reflection inside LRi [%] assessed sound reduction index Rw,P (C, Ctr) 3 [dB] COOL-LITE® XTREME in triple glazing unit CLIMATOP® (6 | 12 | 4 | 12 | 4 mm, 90% Argon, coating on face #2 with PLANITHERM® XN on face #5) on PLANICLEAR® or DIAMANT® Extremely selective solar control coating with reinforced thermal insulation COOL-LITE® K in triple glazing unit CLIMATOP® (6 | 12 | 4 | 12 | 4 mm, 90% Argon, coating on face #2 with PLANITHERM® XN on face #5) on PLANICLEAR® Selective solar control coating with reinforced thermal insulation COOL-LITE® K in triple glazing unit CLIMATOP® (6 | 12 | 4 | 12 | 4 mm, 90% Argon, coating on face #2 with PLANITHERM® XN on face #3 and #5) on PLANICLEAR® Selective solar control coating with thermal insulation COOL-LITE® ST in triple glazing unit CLIMATOP® (6 | 12 | 4 | 12 | 4 mm, 90% Argon, coating on face #2, with PLANITHERM® XN on face #3 and #5) on PLANICLEAR® Solar control glass offering full flexibility for processing Low-E coating in triple glazing unit CLIMATOP® (4 | 12 | 4 | 12 | 4 mm, 90% Argon, coating on face #2, with 4 Solar control coating in contact with PVB modifies performances and aesthetics. Please contact us to get the approved PVB list. 5 Bending results depend on the process; trials should be done for validation. 6 Screen-printing, roller coating, spray, digital printing inks and enamels validation is required. PLANITHERM® XN II DIAMANT® yes extra neutral 75 0.55 0.63 1.36 PLANITHERM® XN DIAMANT® extra neutral 75 0.55 0.63 1.36 PLANITHERM® XN II yes neutral 73 0.53 0.61 1.38 PLANITHERM® XN neutral 73 0.53 0.61 1.38 PLANITHERM® ONE II DIAMANT® yes extra neutral 65 0.46 0.53 1.41 PLANITHERM® ONE DIAMANT® extra neutral 65 0.44 0.51 1.48 PLANITHERM® ONE II yes neutral 64 0.44 0.51 1.45 PLANITHERM® ONE neutral 64 0.43 0.49 1.49 COOL-LITE® ST BRIGHT SILVER DIAMANT® silver 57 0.45 0.51 1.27 COOL-LITE® ST BRIGHT SILVER silver 55 0.43 0.49 1.28 COOL-LITE® ST 167 neutral 55 0.42 0.48 1.31 COOL-LITE® ST 150 neutral 42 0.32 0.37 1.31 COOL-LITE® ST 136 grey 30 0.24 0.27 1.25 COOL-LITE® ST 120 silver 17 0.15 0.17 1.13 COOL-LITE® STB 136 blue 29 0.23 0.27 1.26 COOL-LITE® STB 120 blue 18 0.15 0.17 1.20 COOL-LITE® KN 166 II neutral 55 0.35 0.41 1.57 NEW COOL-LITE® KN 148 II neutral 42 0.28 0.32 1.50 COOL-LITE® KG 137 tempered golden 31 0.24 0.28 1.29 COOL-LITE® KG 137 annealed golden 31 0.24 0.27 1.29 COOL-LITE® KNT 164 neutral 52 0.37 0.42 1.41 COOL-LITE® KNT 155 neutral 43 0.30 0.35 1.43 COOL-LITE® KNT 140 neutral 34 0.23 0.27 1.48 COOL-LITE® KS 147 silver 39 0.26 0.30 1.50 NEW COOL-LITE® KS 146 II silver 38 0.25 0.29 1.52 COOL-LITE® KS 138 II silver 33 0.22 0.25 1.50 14 15 0.7 30.0 32(-1;-5) to be tempered yes 5 15 15 0.7 30.0 32(-1;-5) 14 15 0.7 30.0 32(-1;-5) to be tempered yes 5 14 14 0.7 30.0 32(-1;-5) 25 23 0.7 30.0 32(-1;-5) to be tempered yes 5 25 23 0.7 30.0 32(-1;-5) 25 23 0.7 30.0 32(-1;-5) to be tempered yes 5 25 23 0.7 30.0 32(-1;-5) 34 31 0.7 35.0 36(-1;-5) yes temperable yes yes 5 yes 33 30 0.7 35.0 36(-1;-5) yes temperable yes yes 5 yes 22 22 0.7 35.0 36(-1;-5) yes temperable yes yes 5 yes 20 20 0.7 35.0 36(-1;-5) yes temperable yes yes 5 yes 23 21 0.7 35.0 36(-1;-5) yes temperable yes yes 32 26 0.7 35.0 36(-1;-5) yes temperable yes yes 19 19 0.7 35.0 36(-1;-5) yes temperable yes yes 21 28 0.7 35.0 36(-1;-5) yes temperable yes yes 23 26 0.7 35.0 36(-1;-5) to be tempered 28 20 0.7 3 5.0 36(-1;-5) to be tempered 33 28 0.7 35.0 36(-1;-5) to be tempered 30 26 0.7 35.0 36(-1;-5) 14 11 0.7 35.0 36(-1;-5) temperable yes 17 11 0.7 35.0 36(-1;-5) temperable yes 23 12 0.7 35.0 36(-1;-5) temperable yes 43 33 0.7 35.0 36(-1;-5) 33 18 0.7 35.0 36(-1;-5) to be tempered 39 19 0.7 35.0 36(-1;-5) to be tempered TRIPLE GLAZING UNITS - CLIMATOP® OUR PRODUCTS Values given according to the standards 1 EN 410, 2 EN 673 and 3 EN 12758 processing possibilities coating to be tempered / annelead color in reflection light transmission LT 1 [%] solar factor g-value 1 shading coefficient SC selectivity LT / g screenprinting & enamelling 6 bending 5 lamination tested towards PVB 4 tempering use as mono glazing (coating on surface #2) weight [kg/m 2 ] Ug-value 2 [W/m 2 K] reflection outside LRe [%] reflection inside LRi [%] assessed sound reduction index Rw,P (C, Ctr) 3 [dB] with EASYPRO with EASYPRO with EASYPRO on demand 4 Solar control coating in contact with PVB modifies performances and aesthetics. Please contact us to get the approved PVB list. 5 Bending results depend on the process; trials should be done for validation. 6 Screen-printing, roller coating, spray, digital prin- ting inks and enamels validation is required. 7 COOL-LITE® SKN 154 may have a slight color deviation in transmission with SKN 154 II. Validation of a prototype is recommended if both versions are used on the same façade. 8 This coating can be laminated for use on a façade up to 1,500 m2 and project must be made from a single production batch from SGG.
Made with FlippingBook
RkJQdWJsaXNoZXIy MTMyNDA4